Additional Information

Field Value
Data last updated unknown
Metadata last updated August 30, 2023
Created unknown
Format HTML
License No License Provided
Created2 years ago
Collection frequencyone-time
Collection proceduresWell Design: Water table monitoring wells are installed ~1 m below the baseflow water table. Wells are constructed of 5 cm inner diameter PVC pipe with approximately 1 m long, 0.25 mm slot screen lengths, capped at the bottom.Each site has a network of five wells: A central well (C) and four wells ~40 m from the center well in the four cardinal directions (N, S, E, W). Pressure transducers to log water table levels at 30 minute intervals were deployed in most of the wells at various times. Water Table Data:Site data are listed by acronyms, see above, e.g., BDASn = Bosque del Apache south site, north well. Variables include date, time, groundwater temperature recorded by the transducer, if applicable (gw temp, °C), depth to water table from grade at the well (DWT, cm), water table elevation above sea level (WT elev, m, except for the unsurveyed La Joya site), and a quality check (qc) column to indicate estimated data (see below).Groundwater temperatures range from 8° to 20° C with precision to the nearest tenth of a degree. Water table levels range from 4 m depth to 0.5 m above the surface (inundation) with precision to the nearest mm. Water table levels collected with the following pressure transducers:1. Solinst model 3001 LT M10 Leveloggers and model 3001 LT M1.5 Barologgers*, Solinst Canada Ltd., Georgetown, ON, Canada.2. Schlumberger model DI501 Mini-, model DI701 Cera-, and model DI501 Baro*-Divers, Schlumberger Water Services,Tucson, AZ.3. EEI Submersible Sensor models 2.0 (2 m) and 5.0 (4m), Electronic Engineering Innovations, Las Cruces, NM. These transducers are vented (no barometric correction required) and do not measure temperature.*Solinst and Schlumberger submersible transducers measure total pressure (barometric and hydraulic). Barometric transducers suspended above the water column in a well record barometric pressure, which is subtracted from the total pressure readings to arrive at hydraulic pressure, or well head.With all data collections, well water levels are manually measured with a Solinst or TestWell sounder and offset-corrected. Thirty-minute data missing from a time series indicate that a logger was not deployed or a malfunction occurred. Missing water table data are estimated in some cases, especially when data are lost during the Apr 1 -- Nov 15 growing season and at wells with long-term records. Estimates are made by:1. The average rate of change within a time series from data existing before and/or after the gap (e1 in the qc column).2. The average rate of change from one or more nearby well logs during the gap (e2 in the qc column).3. Linear regression with one or more of the nearby well logs from data existing before and after the gap (e3 in the qc column). Survey of location and elevation of wells:Survey data collected by D. McDonnell, UNM Biology, Feb-Mar 2002, UTM NAD83. Equipment loaned by University NAVSTAR Consortium (UNAVCO), Boulder, CO. Equipment used: Trimble 4000 Receiver Systems (2) $24,000 Trimble 4700 Reciever System (1) $8,000 Trimble Removable Groundplane Antennas (3) $9,000 TSC-1 Controller (1) $5,000 Misc. ancillary equipment $1,000 LARO site only: GPS data collected by J Thibault and J Cleverly, UNM Biology. Garmin Etrex and Garmin III+, WGS 84. Data not suitable for use in elev calculations at these wells. Coordinates and c well elev are approximations.
Collection timeframe1999-2014
Data sourceUniversity of New Mexico
Geographic locationDescription: The northernmost group of wells for SEV295 is at this location. Site Coordinates: Longitude (degree): -106.6882 Latitude (degree): 35.126894
Id247625f1-7283-43f9-a175-6f85e83ab9c1
License idcc-by
Package id4ea8f7a2-3637-46c5-841c-5bd079d73fa9
Position1
Publish methodData portal
Resource contact email[email protected]
Resource contact nameUNM Information Manager
Resource version1
Stateactive