Performer: Pegasus Technologies, Incorporated
Project Description:
Pegasus Technology will demonstrate on a large utility coal fired boiler the ability to affect and optimize mercury speciation and multi-pollutant control using non-intrusive advanced sensor and optimization technologies. The intent of this proposal is to demonstrate plant wide advanced control and optimization systems on a coal fired steam electric power plant in order to minimize emissions while maximizing the efficiency, and byproducts of the plant as an electricity producer. Advanced solutions utilizing state of the art sensors and neural network based optimization and control technologies will be used to maximize the portion of the mercury vapor in the boiler flue gas which is oxidized or captured in particle bonds resulting in lower uncontrolled releases of mercury.
Artificial intelligence and simulation technologies will be used to control and optimize all the major facets of the power plant. This will be accomplished in a novel, modular and cost effective manner. During this project critical sensing devices will be added to the unit. Additional sensors represent a modern addition to the plant engineer's knowledge set and best possible integration of the plant assets. The project team has put together all the required best of class technologies to prove that the mercury speciation and multi-pollutant benefits can be measured, optimized, and controlled. This shall demonstrate an environment that is at once both higher in average compliance, and of better control resulting in both a smaller risk of non-compliance to the utility and minimization of capital. The project is intended to demonstrate how integrating sensors, islands of controls and advanced controls into a total plant solution can lead to improved economics while being environmentally compliant.
This project will also demonstrate that there is minimal if any adverse impacts on the commercial aspects of existing byproducts such as ash and will be directly applicable to the existing coal fleet as well as being integrated into future new plant designs.
The demonstration power plant is equipped with a tangentially-fired boiler rated to supply steam to power a turbine generator with a rated capacity of approximately 890 MW. The unit fires a blend of lignite and Powder River Basin sub-bituminous coal. The unit is also equipped with a cold-side Electrostatic Precipitator (ESP) rated at approximately 99.8% particulate removal efficiency and a wet limestone Flue Gas Desulfurization (FGD) system rated at approximately 90% SO2 removal efficiency. Both of the devices are capable of removing specie optimized mercury from the unit's flue gas.
Location: Chardon, OH